TORQUETRAK 10K-LPLOW PROFILE TORQUE TELEMETRY SYSTEM

Transmit Live Torque Data from a Rotating Shaft

Measuring live torque in real time is easier than ever with the TorqueTrak 10K-LP (Low Profile) telemetry system. Convert virtually any drive shaft into a rotating torque sensor by simply mounting the wireless torque transmitter, battery and a torque sensitive strain gage to the shaft. At only 0.70 inches tall, the TorqueTrak 10K-LP is ideal for applications with very low radial clearance (area around the shaft) such as on vehicle drive shafts.

Use the infrared remote control to adjust transmitter gain, activate the remote shunt calibration or switch the transmitter to standby power mode. The multi-line LCD receiver display and keypad make system adjustments straightforward. Low power consumption in the rugged transmitter allows longer battery life than the TorqueTrak 10K while sophisticated electronics assure accurate and reliable torque data output.

FEATURES & BENEFITS

  • Easy to Use
    Fits any size shaft, any torque level. No machine modifications or disassembly required. Calibration is done off-the-shaft. Receiver display and keypad offer user-friendly interface.
  • Infrared Remote Control
    Control transmitter operation including channel select, gain/range, shunt calibration and low-power standby mode.
  • Reliable Data Transmission
    Clean, noise-free data signal through analog voltage output or digital data output via RS-232.
  • Standby Power Mode
    Extends transmitter battery life without disconnecting battery.
  • 16 Channels
    500 Hz Frequency Response Use; multiple systems simultaneously.
  • Water-Resistant Housing
    Tested to IP67
  • User Adjustable Gain
    Amplify the strain/torque signal to the most useful level.

TORQUETRAK 10K-LP Specification

TX10K-LP-S STRAIN TRANSMITTER

  • SENSOR INPUT:Full (four-arm) Wheatstone Bridge strain gage (350Ω standard)
  • BRIDGE INPUT:3.0 VDC, ±0.1%
  • SENSOR RANGE:User selectable per chart below (chart based on gage factor = 2.0):
TRANSMITTER GAIN FULL BRIDGE
4 ACTIVE ARMS
(TORQUE OR BENDING)
FULL BRIDGE
2.6 ACTIVE ARMS
(TENSION OR COMPRESSION)
1/4 BRIDGE
1 ACTIVE ARM
(SINGLE GAGE)
16000 ±125 MICROSTRAIN ±192 MICROSTRAIN ±500 MICROSTRAIN
8000 ±250 MICROSTRAIN ±385 MICROSTRAIN ±1000 MICROSTRAIN
4000 ±500 MICROSTRAIN ±769 MICROSTRAIN ±2000 MICROSTRAIN
2000 ±1000 MICROSTRAIN ±1538 MICROSTRAIN ±4000 MICROSTRAIN
1000 ±2000 MICROSTRAIN ±3077 MICROSTRAIN ±8000 MICROSTRAIN
500 ±4000 MICROSTRAIN ±6154 MICROSTRAIN ±16000 MICROSTRAIN
SENSOR & POWER CONNECTION
Screw terminal block
TRANSMITTER POWER INPUT
6.0 to 25VDC (9V battery typical)
TRANSMITTER POWER CURRENT
Transmit Mode: 20 mA nom, 200 mW max with 350Ω bridge
Standby Mode: 0.5 mA nom, 8 mW max
TRANSMITTER BATTERY LIFE
48 hours in Transmit Mode (9V lithium, 350Ω bridge, 25℃)
TRANSMISSION FREQUENCY
903-925MHz
TRANSMIT DISTANCE
10 feet or more
G-FORCE RATING
2000 g’s (steady state)
OPERATING TEMPERATURE
-30°– 85℃(-22° – 185℉)
SIZE AND WEIGHT
0.64″x 1.02″x 2.01″, 31 grams

RM10K REMOTE CONTROL

CONTROL FUNCTIONS
Channel select; Gain/Range; Shunt Calibration 1 and 2; Power Standby
TRANSMIT TYPE AND DISTANCE
Infrared; up to 10 feet (for use when transmitter is not rotating)

RX10K RECEIVER

VOLTAGE OUTPUT
±10 VDC, field adjustable 0.25x to 4.0x
5-way binding posts (banana jacks)
DIGITAL OUTPUT CONNECTION
RS232 type DB9 connector (cable provided for PC COM port)
RECEIVER POWER INPUT
12VDC nominal (10 – 18VDC acceptable), 300 mA max
(110VAC or 220VAC adapter provided)
OPERATING TEMPERATURE
-20°– 70℃(-4° – 158℉)
SIZE AND WEIGHT
2.88″ x 5.75″ x 8.50″, 2 lbs (73 mm x 146 mm x 216 mm, 1 kg)

TT10K SYSTEMS

RESOLUTION
14bits
GAIN ERROR1
±0.25%Reading (max), 25℃ ambient
GAIN TEMPERATURE COEFFICIENT1
±0.005%Reading/℃ (max), 0 – 50℃ ambient
OFFSET ERROR1
±0.16%FS (max), 25℃ ambient0.16
OFFSET TEMPERATURE COEFFICIENT1
±0.004%FS/°C (max), 0 – 50℃ ambient
FREQUENCY RESPONSE2
0 – 500 Hz (-3dB @ 500Hz)
DELAY2
4.2 msec, typical
SAMPLE TRANSMISSION RATE
2400 samples/sec

1 TX10K Gain = 4000

2 RX10K filter setting = 500Hz

Specifications are subject to change without notice.